Violation 45
Fire extinguishers proper and sufficient (reporting only)
Florida does not class this family as high priority, which means it is not what makes people ill on its own. It has been recorded 2,938 times, across 6 separate citation codes.
Times recorded2,938
High priority0
Citation codes6
Restaurants2,111
| Code | What it says | Severity | Recorded |
|---|---|---|---|
| 45-02-4 | Fire extinguisher in the red. | Basic | 1,510 |
| 45-04-4 | 2 unit tabletop fryer not under fire suppression system. | Basic | 1,016 |
| 45-05-4 | Fryer not aligned under fire suppression nozzle. | Basic | 282 |
| 45-01-4 | No portable fire extinguisher present. | Basic | 82 |
| 45-06-4 | Portable fire extinguisher placed on bar top. | Basic | 45 |
| 45-03-4 | Audible alarm coming from panel in electrical room. | Basic | 3 |
The same code, written up by different inspectors in different kitchens. Exactly as filed — spelling, punctuation and all.
Use of cooking equipment producing grease laden vapors/smoke with no hood suppression system installed. Notified Fire AHJ. For reporting purposes only. Observed four electric flat grills at kitchen area not located under hood currently installed.
45-04-4SANO FOOD →Aug 26, 2026
Use of cooking equipment producing grease laden vapors/smoke with no hood suppression system installed. Notified Fire AHJ. For reporting purposes only. 3 small fryers located at prep area with no hood suppression system.
45-04-4PERLA'S PIZZA →Aug 26, 2026
Portable fire extinguisher gauge in red zone. For reporting purposes only.
45-02-4IMMACULATE CONSUMPTION →Aug 26, 2026
Portable fire extinguisher gauge in red zone - overcharged Class K in kitchen. For reporting purposes only.
45-02-4BG ROBATA →Aug 26, 2026
Use of cooking equipment producing grease laden vapors/smoke with no hood suppression system installed. Notified Fire AHJ. For reporting purposes only. Observed a counter top fryer in the back of kitchen with no hood suppression system, operator removed fryer.
45-04-4LA MONARCA MICHOACANA →Aug 26, 2026
Portable fire extinguisher gauge in red zone. For reporting purposes only. By rear door, on recharge
45-02-4TACO WAY →Aug 26, 2026
- From initial inspection : Use of cooking equipment producing grease laden vapors/smoke with no hood suppression system installed. Notified Fire AHJ. For reporting purposes only. Flat griddle and propane oven with hood no fire suppression. Using large pan to fry food items with oil.
45-04-4CAFE EXPRESS →Aug 25, 2026
Use of cooking equipment producing grease laden vapors/smoke with no hood suppression system installed. Notified Fire AHJ. For reporting purposes only.
45-04-4TAQUERIA EMANUEL →Aug 25, 2026
Portable fire extinguisher gauge in red zone. For reporting purposes only. Operator used 3 red fire extinguishers and 2 k series extinguishers to assist with putting out the fire at the front entrance.
45-02-4OLD'S HAVANA →Aug 25, 2026
Portable fire extinguisher gauge in red zone. For reporting purposes only. Observed fire extinguisher in the red at back door of restaurant.
45-02-4CAPTAIN DS #3784 →Aug 25, 2026